Micropumps with varying nozzle-diffuser geometry and actuations are being explored for many drug delivery applications. Power consumption and reliability become very critical in the realization of these micropumps. In this study, the performance of a micropump consisting of three nozzle/diffuser elements designed and fabricated from PDMS material and actuated on top by a reciprocal motor was evaluated. The performance characteristics related to the flow rate obtained from testing demonstrated the efficiency of the micropump. The results obtained illustrate the relationship between actuation frequency and fluid flow through the micropump. The effects of fluid viscosity and actuator location were also investigated and the results are presented and discussed.
Keywords: Microfluidics, simulation, actuation, CFD, thermodynamic, Nozzle/Diffuser, PDMS, Micropump, Power consumption, insulin injectors, Design, Fabrication and Testing of a Nozzle/Diffuser PDMS Micropump with Top Actuation
Micro and Nanosystems
Title: Design, Fabrication and Testing of a Nozzle/Diffuser PDMS Micropump with Top Actuation
Volume: 3 Issue: 1
Author(s): Charles P. Cartin and Ramana M. Pidaparti
Affiliation:
Keywords: Microfluidics, simulation, actuation, CFD, thermodynamic, Nozzle/Diffuser, PDMS, Micropump, Power consumption, insulin injectors, Design, Fabrication and Testing of a Nozzle/Diffuser PDMS Micropump with Top Actuation
Abstract: Micropumps with varying nozzle-diffuser geometry and actuations are being explored for many drug delivery applications. Power consumption and reliability become very critical in the realization of these micropumps. In this study, the performance of a micropump consisting of three nozzle/diffuser elements designed and fabricated from PDMS material and actuated on top by a reciprocal motor was evaluated. The performance characteristics related to the flow rate obtained from testing demonstrated the efficiency of the micropump. The results obtained illustrate the relationship between actuation frequency and fluid flow through the micropump. The effects of fluid viscosity and actuator location were also investigated and the results are presented and discussed.
Export Options
About this article
Cite this article as:
P. Cartin Charles and M. Pidaparti Ramana, Design, Fabrication and Testing of a Nozzle/Diffuser PDMS Micropump with Top Actuation, Micro and Nanosystems 2011; 3 (1) . https://dx.doi.org/10.2174/1876402911103010008
DOI https://dx.doi.org/10.2174/1876402911103010008 |
Print ISSN 1876-4029 |
Publisher Name Bentham Science Publisher |
Online ISSN 1876-4037 |
- Author Guidelines
- Graphical Abstracts
- Fabricating and Stating False Information
- Research Misconduct
- Post Publication Discussions and Corrections
- Publishing Ethics and Rectitude
- Increase Visibility of Your Article
- Archiving Policies
- Peer Review Workflow
- Order Your Article Before Print
- Promote Your Article
- Manuscript Transfer Facility
- Editorial Policies
- Allegations from Whistleblowers
Related Articles
-
Stability, Disposition, and Penetration of Catalytic Antioxidants Mn-Porphyrin and Mn-Salen and of Methylprednisolone in Spinal Cord Injury
Central Nervous System Agents in Medicinal Chemistry Development and Potential Utility of Dual and Triple NK Receptor Antagonists
Current Topics in Medicinal Chemistry The Contractile Properties of Airway Smooth Muscle: How their Defects can be Linked to Asthmatic Airway Hyperresponsiveness?
Current Respiratory Medicine Reviews Obstructive Sleep Apnea and Atrial Arrhythmogenesis
Current Cardiology Reviews Mechanistic Approach to Understanding Psychosis Risk in Velocardiofacial Syndrome
Current Pediatric Reviews Progress and Promise of Nur77-based Therapeutics for Central Nervous System Disorders
Current Neuropharmacology Neuroinflammation and Alzheimer's Disease: Implications for Microglial Activation
Current Alzheimer Research Pharmacogenetic Testing for Clopidogrel: State of the ART
Current Pharmacogenomics and Personalized Medicine Inhibition of Histone Deacetylase 6 Protects Hippocampal Cells Against Mitochondria-mediated Apoptosis in a Model of Severe Oxygen-glucose Deprivation
Current Molecular Medicine Free Radicals in Living Systems: In Vivo Detection of Bioradicals with EPR Spectroscopy
Current Organic Chemistry Screening of Synthetic Heterocyclic Compounds as Antiplatelet Drugs
Medicinal Chemistry Intracoronary Injection of Glycoprotein IIb/IIIa, Abciximab, as Adjuvant Therapy in Primary Coronary Intervention
Cardiovascular & Hematological Agents in Medicinal Chemistry Impact of Leukemia Stem Cells Phenotype Expression on Response to Induction Therapy in Acute Myeloid Leukemia Patients
Cardiovascular & Hematological Disorders-Drug Targets CYP4 Enzymes As Potential Drug Targets: Focus on Enzyme Multiplicity, Inducers and Inhibitors, and Therapeutic Modulation of 20- Hydroxyeicosatetraenoic Acid (20-HETE) Synthase and Fatty Acid ω- Hydroxylase Activities
Current Topics in Medicinal Chemistry Treatment of Patients with Schizophrenia and Substance Abuse Disorders
Current Pharmaceutical Design The Right Ventricle: Biologic Insights and Response to Disease
Current Cardiology Reviews Synthesis and Biological Evaluation of Bridged Analogues of the Platelet Aggregation Inhibitor Trifenagrel
Letters in Drug Design & Discovery Renal Heat Shock Proteins Over-Expression Due to Anabolic Androgenic Steroids Abuse
Mini-Reviews in Medicinal Chemistry Motion Analysis of the Carotid Artery Wall and Plaque Using B-Mode Ultrasound
Vascular Disease Prevention (Discontinued) Phage Display Applications for Molecular Imaging
Current Pharmaceutical Biotechnology