Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

Stability Indicating Method for Known and Unknown Impurities Profiling for Vildagliptin in Vildagliptin Tablet

Author(s): Nitin Mahajan*, Suparna Deshmukh and Mazhar Farooqui

Volume 17, Issue 10, 2021

Published on: 16 October, 2020

Page: [1293 - 1302] Pages: 10

DOI: 10.2174/1573412917999201016094821

Price: $65

Abstract

Background: Vildagliptin is a drug for the treatment of diabetes. DPP-IV inhibitor represents a new class of oral antihyperglycemic agents to treat patients with type 2 diabetes. Several RP-HPLC methods have been reported to determine Vildagliptin alone. However, it has been noted that there are no available stability-indicating methods in pharmacopeias (USP/BP/EP/JP) nor in the available literature to quantify known and unknown impurity patterns for vildagliptin in vildagliptin tablets.

Objective: The aim of this study is to develop a new single, sensitive, robust and specific gradient RP-HPLC method to quantify known and unknown impurities and degradants of Vildagliptin in Vildagliptin tablets.

Methods: Chromatographic separation has been accomplished on the Hypersil ODS column (250 x 4.6) mm, 5 μm with a mobile phase consisting of a mixture of Perchloric acid Buffer, methanol, acetonitrile and Triethylamine delivered at a flow rate of 1.0 mL minute-1 and the detection wavelength 210 nm. The developed method was validated as per ICH guidelines.

Results: Vildagliptin was found degraded significantly under oxidative and alkaline stress conditions. The degradation products were well resolved from Vildagliptin and its impurities. An analytical method was found linear, accurate and precise from LOQ (Limit of Quantification) level to 150% of impurity specification limit (0.5%).

Conclusion: The method found sensitive, rapid and accurate quantification of known, unknown impurities and degradants. The peak purity results confirmed that the Vildagliptin peak was homogeneous and pure in all stress samples, thus proving the stability-indicating nature of the method.

Keywords: Impurity profiling, degradation products, analytical method development, analytical method validation, HPLC, related substances, vildagliptin.

Graphical Abstract

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy