Additional Damping Control of a Hybrid Multi-infeed DC System with a Wind Farm

Author(s): Congshan Li, Yan Fang*, Ping He*, Yikai Li and Tingyu Sheng

Volume 14, Issue 2, 2021

Published on: 14 October, 2020

Page: [189 - 197] Pages: 9

DOI: 10.2174/2352096513999201014163901

Price: $65

Abstract

Background: In a hybrid multi-infeed direct current (HMIDC) system, the interaction between the AC and DC systems has an influence on the damping characteristics of the system, while a doubly-fed induction generator (DFIG) based wind turbine connected to the grid complicates the coupling between AC and DC.

Objective: Based on the basic principles of wind power generation and low-frequency oscillation (LFO), a DFIG -based wind turbine is connected to the LCC-HVDC side and VSC-HVSC side of an HMIDC system to study the influence of the oscillation mode on a hybrid system with different wind power access locations, and two kinds of additional DC damping controllers have been designed to suppress the LFO. Moreover, the effects of different additional DC damping controllers on the suppression of the LFO in the system have also been compared.

Methods: First, the total least squares- estimation of signal parameters via rotational invariance techniques (TLS-ESPRIT) was used to obtain the system’s oscillation mode. Second, the transfer function was determined by the Butterworth bandpass filter. Third, the LCC-HVDC and VSC-HVDC additional damping controllers were designed based on the H2/H∞ hybrid control theory.

Results: The designed additional DC damping controller showed a good suppression effect on LFO in the HMIDC system and could meet the system damping deficit. The effect of the LCC-HVDC additional damping controller was observed to be better than that of VSC-HVDC.

Conclusion: Through a simulation analysis on PSCAD/EMTDC simulation software, the effectiveness of the designed additional DC damping controller has been verified.

Keywords: Hybrid multi-infeed DC system, doubly-fed induction generator-based wind turbine, least squares-estimation, rotational invariance techniques, low-frequency oscillation, hybrid control theory, additional DC damping controller.

Graphical Abstract
[1]
H. Linbin, X. Huanhai, H. Wei, Y. Huan, and W. Zhen, "Quantified Analysis Method of Frequency Response Characteristics for Power Systems with Virtual Inertia", Dianli Xitong Zidonghua, vol. 42, no. 08, pp. 31-38, 2018.
[2]
L. Hui, C. Hongwen, Y. Chao, Z. Bin, and T. Xianhu, "A fuzzy additional damping control strategy of DFIG wind farms", Chinese Society for Electrical Engineering, vol. 33, no. 31, pp. 51-57, 2013.
[3]
W. Du, J. Bi, J. Cao, and H.F. Wang, "A Method to Examine the Impact of Grid Connection of the DFIGs on Power System Electromechanical Oscillation Modes", IEEE Trans. Power Syst., vol. 31, no. 5, pp. 3775-3784, 2016.
[http://dx.doi.org/10.1109/TPWRS.2015.2494082]
[4]
A.K. Gupta, K. Verma, and K.R. Niazi, "Dynamic impact analysis of DFIG-based wind turbine generators on low-frequency oscillations in power system", IET Generat. Transm. Distribut., vol. 11, no. 18, pp. 4500-4510, 2017.
[http://dx.doi.org/10.1049/iet-gtd.2017.0308]
[5]
Q. Chao, Z. Yuan, S. Yinsheng, and L. Peng, "Low-frequency oscillatory stability analysis based on security region for Dower system with larae-scale wind power", Power Automat. Equip., vol. 37, no. 05, pp. 100-106, 2017.
[6]
D. Gautam, L. Goel, R. Ayyanar, V. Vittal, and T. Harbour, "Control Strategy to Mitigate the Impact of Reduced Inertia Due to Doubly Fed Induction Generators on Large Power Systems", IEEE Trans. Power Syst., vol. 26, no. 1, pp. 214-224, 2011.
[http://dx.doi.org/10.1109/TPWRS.2010.2051690]
[7]
Z. Ziyong, H. Zhijian, and L. Yonghui, "Design of wide-area damping controller of grid-tied wind generation system based DFIG", Science Press, vol. 37, no. 01, pp. 157-163, 2011.
[8]
Z. Xueguang, Q. Wangming, F. Ran, and X. Danguo, "SSO mitigation method of DFIG based on improved control of converter", Edit. Depart. Electric Mach. Cont., vol. 24, no. 02, pp. 1-9, 2020.
[9]
Y.J. Isbeih, M.S. El Moursi, W. Xiao, and E. El-Saadany, "H∞ mixed-sensitivity robust control design for damping low-frequency oscillations with DFIG wind power generation", IET Generat. Transm. Distribut., vol. 13, no. 19, pp. 4274-4286, 2019.
[http://dx.doi.org/10.1049/iet-gtd.2018.6433]
[10]
D. Yuanyuan, L. Tianqi, G. Feng, and L. Xingyuan, "Multi-Channel HVDC Supplementary Damping Controller Design Based on Multi-Stage Linear Quadratic Regulator Method", Chinese Machine, vol. 32, no. 06, pp. 76-84, 2017.
[11]
M. Edrah, K.L. Lo, and O. Anaya-Lara, "“Reactive power control of DFIG wind turbines for power oscillation damping under a wide range of operating conditions”, IET Generat", Transm. Distribut., vol. 10, no. 15, pp. 3777-3785, 2016.
[http://dx.doi.org/10.1049/iet-gtd.2016.0132]
[12]
M. Ahmed, A. Vahidnia, M. Datta, and L. Meegahapola, "An Adaptive Power Oscillation Damping Controller for a Hybrid AC/DC Microgrid", IEEE Access, vol. 8, pp. 69482-69495, 2020.
[http://dx.doi.org/10.1109/ACCESS.2020.2985978]
[13]
Z. Xiaodong, S. Lei, and C. Ning, "etc. “An analysis on low voltage ride through of wind turbine driven doubly fed induction generator with different resistances and quitting time of Crowbar", Dianli Xitong Zidonghua, vol. 34, no. 18, pp. 84-89, 2010.
[14]
X. Yin, C. Ying, and S. Mei, "Review on wind turbine models for power system transient simulations", Dianli Xitong Zidonghua, vol. 35, no. 9, pp. 100-107, 2011.
[15]
Z. Shuang, Z. Xueyang, B. Cunxi, T. Bei, L. Baohong, and L. Tianqi, "Based on the hybrid H_2/H_∞ control theory of the AC-DC parallel system machine network damping coordinated control", Electric. Measure. Instrument., vol. 55, no. 05, pp. 57-62, 2018.
[16]
Y. Li, "Robust control-processing method of linear matrix inequality", In: , Beijing: Tsinghua University, 2002.
[17]
B. Xu, and Z. Zheng, "SVD filtering and TLS-ESPRIT algorithm based on stator fault characteristic detection of doubly-fed induction generator", J. Eng., vol. 7, no. 18, pp. 5193-5196, 2019.
[http://dx.doi.org/10.1049/joe.2018.9265]
[18]
N. Binye, X. Wang, and L. Xiaojun, "Low-frequency oscillation suppression using flexible DC grid based on state feedback supplementary damping control", Electric Power Automat. Equip., vol. 39, no. 03, pp. 45-50, 2019.
[19]
Z. Rui, L. Xingyuan, and L. Tianqi, "Design of multi-channel DC supplementary damping controller for subsynchronous and low-frequency oscillation suppression", Electric Power Automat. Equip., vol. 34, no. 3, pp. 89-93, 2014.
[20]
J. Chen, and T. Jin, "MOHAMED A. MOHAMED, W. Mengqi. “An Adaptive TLS-ESPRIT Algorithm Based on an S-G Filter for Analysis of Low Frequency Oscillation in Wide Area Measurement Systems", IEEE Access, vol. 2019, no. 07, pp. 47644-476548, 2019.
[http://dx.doi.org/10.1109/ACCESS.2019.2908629]
[21]
G. Jun, W. Lei, and Z. Wen, "Study on operating behavior and suppression strategy of doubly-fed induction generators wind turbine under harmonic grid voltage conditions", Power Syst. Protect. Cont., vol. 44, no. 23, pp. 164-169, 2019.

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy