Generic placeholder image

Recent Patents on Engineering

Editor-in-Chief

ISSN (Print): 1872-2121
ISSN (Online): 2212-4047

General Research Article

Simple Threshold Method in Fault Diagnosis for Voltage Source Inverter in a Direct Torque Control Induction Motor Drive

Author(s): Farid Kadri* and Mohamed A. Hamida

Volume 14, Issue 4, 2020

Page: [598 - 609] Pages: 12

DOI: 10.2174/1872212113666191002121902

Price: $65

Abstract

Background: The need for a diagnosis today, becomes a necessity for variable speed AC drives in several industrial applications. An important research axis is oriented towards monitoring the state of the converter supplying the electric motor. Indeed, the voltage source inverter is likely to have switching faults. Therefore, an emergency stop of the motor drive must be done.

Objective: After reviewing related patents and works, the objective of this paper is to identify the feasibility of fault detection and diagnosis in a three-phase inverter feeding an induction motor.

Method: The proposed approach is a simple threshold fault classification method applied to fault diagnosis of a Direct Torque Control (DTC) induction motor drive using the stator Concordia mean current vector. With a fault occurrence, a localization domain consisting of seven patterns is constructed.

Results: Simulated results on 1.5-kW induction motor drive show the effectiveness of the proposed approach with a good classification performance.

Conclusion: The classification performance of our simple diagnosis system is acceptable for one fault occurrence compared to other methods. Faulty switch detection and identification is completed within a few periods of current. Using intelligent technique should improve classification performances for multiple faults occurrence.

Keywords: Fault diagnosis, Direct Torque Control (DTC), Voltage Source Inverter (VSI), feature extraction, threshold fault classification, induction motor.

Graphical Abstract

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy