A Human Fall Detection System Using Continuous Wave Radar

Author(s): Alpesh Vala*, Amit Patel and Mihir James

Volume 10, Issue 6, 2020

Page: [866 - 874] Pages: 9

DOI: 10.2174/2210327909666190611143215

Price: $65

Abstract

Background & Objective: In this paper contactless human fall detection system has been designed, developed and tested.

Methods: Continuous wave radar system is implemented at 2.10 GHz of frequency. It consists of transmitter and receiver section. In Radio Frequency (RF) transmitter system is developed with the use of frequency synthesizer, power amplifier and patch antenna for the transmission of 2.10 GHz. Similarly, at the receiver side 2.1001GHz of frequency signal is generated with the use of frequency synthesizer. For the measurement of the fall detection high frequency signal is down converted to 100 KHz of signal with the use of mixer. Number of experiment has been performed for the measurement of fall detection. Here non-living object has been used for the experimental purpose.

Results & Conclusion: A fall event has been detected according to the change in the received frequency in respect with the reference frequency.

Keywords: Continuous wave radar, fall detection, Field Programmable Gate Array (FPGA), frequency synthesizer, radar sensor, transmitter.

Graphical Abstract
[1]
Watch. Senior, Fall detector: Case study of european ist seniorwatch project. Tech Rep, Senior Watch 2001.
[2]
Debard G, Mertens M, Goedemé T, Tuytelaars T, Vanrumste B. Three ways to improve the performance of real-life camera-based fall detection systems. J Sens 2017 2017.
[http://dx.doi.org/10.1155/2017/8241910]
[3]
Redd JL, Zura RD, Tanner AE, Walk EE, Wu MM, Edlich RF. Personal emergency response systems. J Burn Care Rehabil 1992; 13(4): 453-9.
[http://dx.doi.org/10.1097/00004630-199207000-00013] [PMID: 1429819]
[4]
Alhimale L, Zedan H, Al-Bayatti A. The implementation of an intelligent and video-based fall detection system using a neural network. Appl Soft Comput 2014; 18: 59-69.
[http://dx.doi.org/10.1016/j.asoc.2014.01.024]
[5]
Belshaw M, Taati B, Snoek J, Mihailidis A. Towards a single sensor passive solution for automated fall detection. Annual International Conference of the IEEE Engineering in Medicine and Biology Society; 2011; Boston, MA 1773-6.
[http://dx.doi.org/10.1109/IEMBS.2011.6090506]
[6]
Feng P, Yu M, Naqvi SM, Chambers JA. Deep learning for posture analysis in fall detection. 19th International Conference on Digital Signal Processing 2014 12-7.
[http://dx.doi.org/10.1109/ICDSP.2014.6900806]
[7]
Feng W, Liu R, Zhu M. Fall detection for elderly person care in a vision-based home surveillance environment using a monocular camera. Signal Image Video P 2014; 8(6): 1129-38.
[http://dx.doi.org/10.1007/s11760-014-0645-4]
[8]
Yang L, Ren Y, Hu H, Tian B. New fast fall detection method based on spatio-temporal context tracking of head by using depth images Sensors (Basel) 2015; 15(9): 23004-19.
[http://dx.doi.org/10.3390/s150923004] [PMID: 26378540]
[9]
Zhang Z, Conly C, Athitsos V. A survey on vision-based fall detection. Proceedings of the 8th ACM international conference on PErvasive technologies related to assistive environments 2015. 1-7.
[10]
Madhubala J, Sree A, Umamakeswari B, Jenita Amali R. A survey on technical approaches in fall detection system. Natl J Physiol Pharm Pharmacol 2015; 5(4): 275.
[http://dx.doi.org/10.5455/njppp.2015.5.0506201550]
[11]
Adib F, Mao H, Kabelac Z, Katabi D, Miller RC. Smart homes that monitor breathing and heart rate. Proceedings of the 33rd annual ACM conference on human factors in computing systems 2015. 837-46.
[http://dx.doi.org/10.1145/2702123.2702200]
[12]
Chen K-M, Misra D, Wang H, Chuang HR, Postow E. An X-band microwave life-detection system. IEEE Trans Biomed Eng 1986; 33(7): 697-701.
[http://dx.doi.org/10.1109/TBME.1986.325760] [PMID: 3733127]
[13]
Levitas B, Matuzas J. UWB radar for breath detection. 11th international radar symposium 2010; IEEE: 1-3.
[14]
Yang Xiaofeng. Sun Guanghao. Non-contact acquisition of respiration and heart rates using doppler radar with time domain peakdetection algorithm. 39th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) 2017 IEEE 2847-50.
[15]
Chen K-M, Huang Y, Zhang J, Norman A. Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier. IEEE Trans Biomed Eng 2000; 47(1): 105-14.
[http://dx.doi.org/10.1109/10.817625] [PMID: 10646285]
[16]
Huang M-C, Liu JJ, Xu W, et al. A self-calibrating radar sensor system for measuring vital signs. IEEE Trans Biomed Circuits Syst 2016; 10(2): 352-63.
[http://dx.doi.org/10.1109/TBCAS.2015.2411732 ] [PMID: 26011865]
[17]
Carlos G. Bilich Bio-medical sensing using ultra wideband communications and radar technology: a feasibility study Pervasive Health Conference and Workshops 2006; IEEE:. pp. 1-9.
[http://dx.doi.org/10.1109/PCTHEALTH.2006.361671]
[18]
Chen Y, Gunawan E, Low KS, et al. Kim Y , Soh C B , Leyman A R , Thi L L Non-invasive respiration rate estimation using ultra-wideband distributed cognitive radar system. International Conference of the IEEE Engineering in Medicine and Biology Society 2006 IEEE. pp. 920-923.
[19]
Best RE, Best RG. Phase-locked loops: theory design and applications. In: McGraw-Hill New York. 1993.
[20]
Balanis RE, Constantine A, Best RG. Antenna theory: analysis and design. In: John Wiley & Sons New York. 2016.

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy