Improvement of Gain Accuracy and CMRR of Low Power Instrumentation Amplifier Using High Gain Operational Amplifiers

Author(s): Rashmi Sahu*, Maitraiyee Konar and Sudip Kundu

Volume 12, Issue 3, 2020

Page: [168 - 174] Pages: 7

DOI: 10.2174/1876402912666200123153318

Abstract

Background: Sensing of biomedical signals is crucial for monitoring of various health conditions. These signals have a very low amplitude (in μV) and a small frequency range (<500 Hz). In the presence of various common-mode interferences, biomedical signals are difficult to detect. Instrumentation amplifiers (INAs) are usually preferred to detect these signals due to their high commonmode rejection ratio (CMRR). Gain accuracy and CMRR are two important parameters associated with any INA. This article, therefore, focuses on the improvement of the gain accuracy and CMRR of a low power INA topology.

Objective: The objective of this article is to achieve high gain accuracy and CMRR of low power INA by having high gain operational amplifiers (Op-Amps), which are the building blocks of the INAs.

Methods: For the implementation of the Op-Amps and the INAs, the Cadence Virtuoso tool was used. All the designs and implementation were realized in 0.18 μm CMOS technology.

Results: Three different Op-Amp topologies namely single-stage differential Op-Amp, folded cascode Op-Amp, and multi-stage Op-Amp were implemented. Using these Op-Amp topologies separately, three Op-Amp-based INAs were realized and compared. The INA designed using the high gain multistage Op-Amp topology of low-frequency gain of 123.89 dB achieves a CMRR of 164.1 dB, with the INA’s gain accuracy as good as 99%, which is the best when compared to the other two INAs realized using the other two Op-Amp topologies implemented.

Conclusion: Using very high gain Op-Amps as the building blocks of the INA improves the gain accuracy of the INA and enhances the CMRR of the INA. The three Op-Amp-based INA designed with the multi-stage Op-Amps shows state-of-the-art characteristics as its gain accuracy is 99% and CMRR is as high as 164.1 dB. The power consumed by this INA is 29.25 μW by operating on a power supply of ±0.9V. This makes this INA highly suitable for low power measurement applications.

Keywords: Instrumentation amplifier, operational amplifier, differential amplifier, folded cascode amplifier, differential mode gain, common-mode gain, CMRR.

Graphical Abstract
[1]
Chow, H.; Wang, J. High CMRR instrumentation amplifier for biomedical applications. 9th International Symposium on Signal Processing and its Applications, Sharjah, pp. 1-4.2007
[http://dx.doi.org/10.1109/ISSPA.2007.4555532]
[2]
Textbook, M.A. Biomedical Signal Processing; Academic Press: Cambridge, Massachusetts, US, 1994.
[3]
Smith, J.I. Modern operational circuit design; Wiley: New York, 1971, pp. 124-126.
[4]
Smither, M.A.; Pugh, D.R.; Woolard, L.M. CMRR analysis of the 3-op-amp instrumentation amplifier. Electron. Lett., 1977, 13(20), 594.
[http://dx.doi.org/10.1049/el:19770427]
[5]
Ramakant, A.G. Op-Amps and Linear Integrated Circuits, 4th ed; Pearson Education, 2015.
[6]
Huijsing, J.H. Operational Amplifiers – Theory and Design; Springer: Berling, Germany, 2000.
[7]
Malhotra, S.; Mishra, A.; Rakesh, B.R.; Gupta, A. Frequency compensation in two-stage operational amplifiers for achieving high 3-dB bandwidth. 2013 IEEE Asia Pacific Conference on Postgraduate Research in Microelectronics and Electronics (PrimeAsia), 2013, pp. 107-110.
[http://dx.doi.org/10.1109/PrimeAsia.2013.6731187]
[8]
Harb, A.; Sawan, M. New low-power low-voltage high-CMRR CMOS instrumentation amplifier. 1999 IEEE International Symposium on Circuits and Systems (ISCAS), 1999, Vol. 6, pp. 97-100.
[http://dx.doi.org/10.1109/ISCAS.1999.780104]
[9]
Goswami, M.; Khanna, S. DC suppressed high gain active CMOS instrumentation amplifier for biomedical application. 2011 International Conference on Emerging Trends in Electrical and Computer Technology, Nagercoil, pp. 747-751.2011
[http://dx.doi.org/10.1109/ICETECT.2011.5760217]
[10]
Yen, C-J.; Chung, W-Y.; Chi, M.C. Micro-power low-offset instrumentation amplifier IC design for biomedical system applications. IEEE Trans. Circuits Syst. I Regul. Pap., 2004, 51(4), 691-699.
[http://dx.doi.org/10.1109/TCSI.2004.826208]
[11]
Zhang, K.; Wu, D. A high-performance folded cascode amplifier. International Conference on Computer and Automation Engineering, 2011, 13, 4026-4029.
[12]
Stout, D.F.; Kaufman, M. Handbook of operational amplifier circuit design; McGraw-Hill: New York, 1976.
[13]
Goel, A.; Singh, G. Novel high gain low noise CMOS instrumentation amplifier for biomedical applications. 2013 International Conference on Machine Intelligence and Research Advancement Katra, 2013, 392-396.
[http://dx.doi.org/10.1109/ICMIRA.2013.83]
[14]
Silverio, A.A.; Chung, W-Y.; Tsai, V.F.S. A low power high CMRR CMOS instrumentation amplifier for Bio-impedance Spectroscopy. IEEE International Symposium on Bioelectronics and Bioinformatics (IEEE ISBB), , 2014; pp. 1-4.
[15]
Fan, Q.; Sebastiano, F.; Huijsing, J.H.; Makinwa, K.A.A. A 1.8μW 60 nV/√Hz capacitively-coupled chopper instrumentation amplifier in 65 nm CMOS for Wireless Sensor Nodes. IEEE J. Solid-State Circuits, 2011, 46(7), 1534-1543.
[http://dx.doi.org/10.1109/JSSC.2011.2143610]
[16]
Huang, G.; Yin, T.; Wu, Q.; Zhu, Y.; Yang, H.A. 1.3μW 0.7μVRMS chopper current-reuse instrumentation amplifier for EEG applications. 2015 IEEE International Symposium on Circuits and Systems (ISCAS), Lisbon2015, pp. 2624-2627.
[http://dx.doi.org/10.1109/ISCAS.2015.7169224]
[17]
Lee, H-S.; Nguyen, V.N.; Pham, X.L.; Lee, J-W.; Park, H-K.A 250-µW, 18-nV/rtHz current-feedback chopper instrumentation amplifier in 180-nm cmos for high-performance bio-potential sensing applications. Analog Integr. Circuits Signal Process., 2016, 90(1), 137-148.
[http://dx.doi.org/10.1007/s10470-016-0853-7]
[18]
Bai, W.; Zhu, Z.A 0.5-V power-efficient low-noise CMOS instrumentation amplifier for wireless biosensor. Microelectronics J., 2016, 51, 30-37.
[http://dx.doi.org/10.1016/j.mejo.2016.02.007]
[19]
Wu, J.; Law, M-K.; Mak, P-I.; Martins, R.P.A 2 μW 45-nV/vHz readout front end with multiple-chopping active-high-pass ripple reduction loop and pseudofeedback DC servo loop, IEEE Trans. Circuits Syst. II. Exp. Briefs, 2016, 63(4), 351-355.
[20]
Zheng, J.; Ki, W.; Hu, L.; Tsui, C. Chopper capacitively coupled instrumentation amplifier capable of handling large electrode offset for biopotential recordings. IEEE Trans. Circuits Syst., II Express Briefs, 2017, 64(12), 1392-1396.
[http://dx.doi.org/10.1109/TCSII.2017.2741348]
[21]
Nagulapalli, R.; Hayatleh, K.; Barker, S.; Zourob, S.; Yassine, N.; Raparthy, S.; Tammam, A. A novel high CMRR trans-impedance instrumentation amplifier for biomedical applications. Analog Integr. Circuits Signal Process., 2018, 98(2), 233-241.
[http://dx.doi.org/10.1007/s10470-018-1256-8]

© 2024 Bentham Science Publishers | Privacy Policy