Generic placeholder image

Recent Advances in Electrical & Electronic Engineering

Editor-in-Chief

ISSN (Print): 2352-0965
ISSN (Online): 2352-0973

Research Article

Voltage Sag Detection in Grid-Connected Photovoltaic Power Plant for Low Voltage Ride-Through Control

Author(s): Ali Qasem Al-Shetwi* and Muhamad Zahim Sujod

Volume 12, Issue 4, 2019

Page: [384 - 392] Pages: 9

DOI: 10.2174/2352096511666180626151223

Price: $65

Abstract

Background: Due to the high level of photovoltaic power plants (PVPPs) penetration into power grids, disconnections of these plants during faults are no longer possible as it may cause problems concerning stability, quality, and operation of the power system. Therefore, new grid codes have been established with low voltage ride-through (LVRT) capability standard requirements for grid-connected PVPPs that should be met. Therefore, for an efficient LVRT control, the fast and precise sag detection strategy is essential for the system to switch from normal operation to LVRT mode of operation.

Methods: For this purpose, this paper presents a two automatic fault detection methods which are RMS-based (d-q) components of grid voltage and positive sequence voltage. These methods were utilized to determine the beginning and end of a voltage sag and to determine the sag depth to regulate the required reactive current that should be injected according to the LVRT standard requirements. The operating method depends on calculating present grid voltage under faults to the nominal voltage that identifies the sags’ depth and therefore inject the required amount of reactive power accordingly. Also, a comparison between the two proposed methods regarding response speed and accuracy was made. The effectiveness of these detection strategies is that it can be integrated into the voltage source inverter (VSI) without utilizing additional external hardware or software programming.

Results: The simulation results demonstrated a good precision and how straightforward the proposed methods’ usage is, proving that the RMS method is faster and more accurate than positive sequence method.

Conclusion: In conclusion, it was found that RMS detection algorithm is preferred for a more accurate and efficient LVRT control.

Keywords: Photovoltaic power plant, sag detection, grid faults, low voltage-ride through, PV inverter, grid codes.

« Previous
Graphical Abstract
[1]
A.Q. Al-Shetwi, M.Z. Sujod, A.A. Tarabsheh, and I.A. Altawi, "Design and economic evaluation of electrification of small villages in rural area in Yemen using stand-alone PV system", Int. J. Renew. Energy Res (IJRER)., vol. 6, no. 1, pp. 1442-1451, 2016.
[2]
J. Pacas, M. Molina, and E. Dos Santos, "Design of a robust and efficient power electronic interface for the grid integration of solar photovoltaic generation systems", Int. J. Hydrogen Energy, vol. 37, pp. 10076-10082, 2012.
[3]
M. Obi, and R. Bass, "Trends and challenges of grid-connected photovoltaic systems-A review", Renew. Sustain. Energy Rev., vol. 58, pp. 1082-1094, 2016.
[4]
A. Cabrera-Tobar, E. Bullich-Massagué, M. Aragüés-Peñalba, and O. Gomis-Bellmunt, "Review of advanced grid requirements for the integration of large scale photovoltaic power plants in the transmission system", Renew. Sustain. Energy Rev., vol. 62, pp. 971-987, 2016.
[5]
A.Q. Al-Shetwi, M.Z. Sujod, and R.N. Lina, "A review of the fault ride through requirements in different grid codes concerning penetration of PV system to the electric power network", ARPN J. Eng. Appl. Sci., vol. 10, pp. 9906-9912, 2015.
[6]
A.Q. Al-Shetwi, and M.Z. Sujod, "Modeling and control of gridconnected photovoltaic power plant with fault ride-through capability", J. Sol. Energy Eng. Trans.-ASME. vol. 140, pp. 021001, 2018.
[7]
A.Q. Al-Shetwi, M.Z. Sujod, and F. Blaabjerg, "Low voltage ride-through capability control for single-stage inverter-based grid-connected photovoltaic power plant", Sol. Energy, vol. 159, pp. 665-681, 2018.
[8]
"O.-K. Teresa, F. Blaabjerg and R. Jose. Advanced and intelligent control in power electronics and drives”, In: Recent research on advanced and intelligent control in power electronics and drives", Springer. vol. 531, 2014.
[9]
A. Pigazo, M. Liserre, R.A. Mastromauro, V.M. Moreno, and A. Dell’Aquila, "Wavelet-based islanding detection in grid-connected PV systems", IEEE Trans. Ind. Electron., vol. 56, pp. 4445-4455, 2009.
[10]
F-S. Pai, and S-J. Huang, "A detection algorithm for islanding-prevention of dispersed consumer-owned storage and generating units", IEEE Trans. Energ. Convers., vol. 16, pp. 346-351, 2001.
[11]
W. Chine, A. Mellit, A.M. Pavan, and S. Kalogirou, "Fault detection method for grid-connected photovoltaic plants", Renew. Energy, vol. 66, pp. 99-110, 2014.
[12]
J-P. Charles, F. Hannane, H. El-Mossaoui, A. Zegaoui, T. Nguyen, P. Petit, and M. Aillerie, "Faulty PV panel identification using the Design of Experiments (DoE) method", Int. J. Electr. Power Energy Syst., vol. 57, pp. 31-38, 2014.
[13]
S. Silvestre, A. Chouder, and E. Karatepe, "Automatic fault detection in grid connected PV systems", Sol. Energy, vol. 94, pp. 119-127, 2013.
[14]
Y. Yang, F. Blaabjerg, and Z. Zou, "Benchmarking of grid fault modes in single-phase grid-connected photovoltaic systems", IEEE Trans. Ind. Appl., vol. 49, pp. 2167-2176, 2013.
[15]
Y. Yang, and F. Blaabjerg, "Low-voltage ride-through capability of a single-stage single-phase photovoltaic system connected to the low-voltage grid", Int. J. Photoenergy, vol. 2013, pp. 1-9, 2013.
[16]
M.B. Latran, and A. Teke, "A novel wavelet transform based voltage sag/swell detection algorithm", Int. J. Electr. Power Energy Syst., vol. 71, pp. 131-139, 2015.
[17]
B. Singh, A. Chandra, and K. Al-Haddad, Power quality: Problems and mitigation techniques., 3rd ed John Wiley & Sons: New York, 2014.
[18]
S. Arias-Guzmán, O.A. Ruiz-Guzmán, L.F. Garcia-Arías, M. Jaramillo-Gonzáles, P.D. Cardona-Orozco, and A.J. Ustariz-Farfán, "Analysis of voltage sag severity case study in an industrial circuit", IEEE Trans. Ind. Appl., vol. 53, pp. 15-21, 2017.
[19]
E. Fuchs, and M.A. Masoum, "Power quality in power systems and electrical machines Scient Direct", 2008.
[20]
A.Q. Al-Shetwi, and M.Z. Sujod, "Modeling and dynamics study of large scale PV system connected Malaysian grid under different fault conditions, In:", International Conference on Advances in Electrical, Electronic and Systems Engineering (ICAEES). Putrajaya, Malaysia, 2016, pp. 488-494.
[21]
A.Q. Al-Shetwi, and M.Z. Sujod, "Sizing and design of PV array for photovoltaic power plant connected grid inverter, In", 3rd National Conference on Postgraduate Research. Pekan, Malaysia, 2016, pp. 193-199.
[22]
H. Wu, and X. Tao, "Three phase photovoltaic grid-connected generation technology with MPPT function and voltage control, In", International Conference on Power Electronics and Drive Systems (PEDS). Taipei, Taiwan, 2009, pp. 1295-1300.
[23]
L. Hassaine, "E. OLias, J. Quintero, and V. Salas, “Overview of power inverter topologies and control structures for grid connected photovoltaic systems", Renew. Sustain. Energy Rev., vol. 30, pp. 796-807, 2014.
[24]
T. Neumann, and I. Erlich, "Modelling and control of photovoltaic inverter systems with respect to German grid code requirements", In", IEEE Power and Energy Society General Meeting. San Diego, CA, USA, 2012, pp. 1-8.
[25]
A.Q. Al‐Shetwi, and M.Z. Sujod, "Grid‐connected photovoltaic power plants: A review of the recent integration requirements in modern grid codes", Int. J. Energy Res., vol. 42, no. 5, pp. 1849-1865, 2018.

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy