Generic placeholder image

Current Pharmaceutical Analysis

Editor-in-Chief

ISSN (Print): 1573-4129
ISSN (Online): 1875-676X

Research Article

Development and Validation of a Simple High-Performance Liquid Chromatography Method for Estimation of Felodipine in Rabbit Plasma: Application to Pharmacokinetic Study

Author(s): Murali Monohar Pandey, Shrikant Y. Charde*, A. Jaipal, Prashant P. Raut, Puneet Goel and Love Kumar

Volume 13, Issue 4, 2017

Page: [321 - 327] Pages: 7

DOI: 10.2174/1573412912666160824120801

Price: $65

Abstract

Background: A new, simple, specific and sensitive reverse-phase liquid chromatographic method was developed and validated for the estimation of felodipine (FDP) in rabbit plasma using fluorescence detector.

Materials and Methods: Plasma standard were prepared using a simple and one-step protein precipitation method and 50 μ l of the standard solutions were injected into the column. The method was found to be linear in the concentration range of 10–1000 ng/ml. The developed bioanalytical method was validated as per standard guidelines. Validation study results demonstrated accuracy, precision, sensitivity and selectivity of the proposed method.

Results: The developed method was successfully employed in the determination of FDP in plasma samples obtained from the pharmacokinetic study of the immediate release tablets in rabbits.

Keywords: Felodipine, fluorescence detector, high-performance liquid chromatography, rabbit plasma, pharmacokinetic study, oral tablet.

Next »
Graphical Abstract

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy