Generic placeholder image

Current Analytical Chemistry

Editor-in-Chief

ISSN (Print): 1573-4110
ISSN (Online): 1875-6727

Research Article

Design Space of a Rapid Colorimetric Microplate Bioassay for Bacitracin Using Response Surface Methodology (RSM)

Author(s): Fabiane L. Francisco, Alessandro M. Saviano, Terezinha J. A. Pinto and Felipe R. Lourenco

Volume 12, Issue 6, 2016

Page: [620 - 627] Pages: 8

DOI: 10.2174/1573411012666160112230407

Price: $65

Abstract

Background: Microbiological assay is the gold-standard method for analyzing antibiotics, since it ensures the success of antimicrobial therapy. However, this method may be time-consuming and it remains almost unaltered since it was first developed. Here, we present the design space of a rapid microplate bioassay for bacitracin.

Methods: Triphenyltetrazolium chloride was used in the bioassay to provide faster response. Factorial design and response surface methodologies were used to optimize microorganism, inoculum proportion, culture medium composition, bacitracin concentration, and triphenyltetrazolium chloride concentration.

Results: Yeast extract amount in culture medium was a key factor in reducing incubation time and it allowed the development of a faster bioassay. In addition, inoculum proportion was a critical parameter. On the other hand, triphenyltetrazolium chloride concentration did not affect the bioassay response. The bioassay was linear, accurate, precise and robust.

Conclusion: Besides being equivalent to an agar diffusion assay according to statistical analysis, the colorimetric bioassay requires less culture medium and solutions, and provides faster results.

Keywords: Analytical quality by design, bacitracin, design space, microbiological assay, response surface methodology.

Graphical Abstract

Rights & Permissions Print Cite