Generic placeholder image

Current Medical Imaging

Editor-in-Chief

ISSN (Print): 1573-4056
ISSN (Online): 1875-6603

Research Article

Radiation Exposure of Anaesthetists Visualised by Real-time Dosimetry

Author(s): Marcus Christian Müller*, Michael Windemuth, Sophie Frege and Eva Nadine Striepens

Volume 15, Issue 2, 2019

Page: [220 - 226] Pages: 7

DOI: 10.2174/1573405613666171123151711

Price: $65

Abstract

Background: Chronic exposure to occupational ionising radiation is seen as one reason for elevated cancer prevalence.

Objective: The aim of this retrospective study was to evaluate radiation exposure of anaesthetists by real-time dosimetry.

Methods: Data of 296 patients were analyzed. Ten types of trauma operation procedures including osteosynthesis of upper and lower extremity fractures and minimally invasive stabilisation of traumatic and osteoporotic vertebral fractures were accomplished. Evaluation was performed by an occupational dosimetry system, which visualises anaesthetists radiation exposure feedback compared to surgeons in real-time.

Results: A significantly lower radiation exposure to anaesthetists compared to surgeons was observed in four types of operative procedures: Plate fixation of proximal humerus fractures, osteosynthesis of proximal femoral fractures, stabilisation of traumatic and osteoporotic vertebral fractures. In four types of operations (plate osteosynthesis of proximal humeral, distal radial and tibial fractures and intramedullary nailing of the clavicle), anaesthetists` amount of radiation exceeded one-third of the surgeons' exposure, especially if the C-arm tube was positioned close to the anaesthetists work station at the patients' head.

Conclusion: By using the occupational radiation dose monitoring system, radiation exposure to anaesthetists was visualised in real-time during trauma operations. Radiation exposure of anaesthetists depends on the type of operation and the position of the C-arm. The system may help to increase anaesthetists` awareness concerning radiation exposure and to enhance compliance in using radiation protection techniques.

Keywords: Chronic exposure, real-time dosimetry, proximal humeral, distal radial and tibial fractures, intramedullary nailing, clavicle, Radiation exposure, C-arm, radiation protection techniques.

Graphical Abstract
[1]
Khan IA, Kamalasekaran S, Fazal MA. Risk of ionising radiation to trainee orthopaedic surgeons. Acta Orthop Belg 2012; 78(1): 106-10.
[2]
Kesavachandran CN, Haarmann F, Nienhaus A. Radiation exposure of eyes, thyroid gland and hands in orthopaedic staff: A systematic review. Eur J Med Res 2012; 17: 28.
[3]
Müller MC, Welle K, Strauss AC, et al. Real-time dosimetry reduces radiation exposure of orthopaedic surgeons. Orthop Traumatol Surg Res 2014; 100(8): 947-51.
[4]
Müller MC, Strauss A, Pflugmacher R, et al. Evaluation of radiation exposure of personnel in an orthopaedic and trauma operation theatre using the new real-time dosimetry system. “dose aware. Z Orthop Unfall 2014; 152(4): 381-8.
[5]
Giannoudis PV, McGuigan J, Shaw DL. Ionisation radiation during internal fixation of extracapsular neck of femur fractures. Injury 1998; 29(6): 469-72.
[6]
Riley SA. Radiation exposure from fluoroscopy during orthopaedic surgical procedures. Clin Orthop Relat Res 1989; (248): 257-60.
[7]
Hafez MA, Smith RM, Matthews SJ, Kalap G, Sherman KP. Radiation exposure to the hands of orthopaedic surgeons: Are we underestimating the risk? Arch Orthop Trauma Surg 2005; 125(5): 330-5.
[8]
Theocharopoulos N, Perisinakis K, Damilakis J, Papadokostakis G, Hadjipavlou A, Gourtsoyiannis N. Occupational exposure from common fluoroscopic projections used in orthopaedic surgery. J Bone Joint Surg Am 2003; 85-A(9): 1698-703.
[9]
Abas AA, Rahman RA, Yahya N, Kamaruzaman E, Zainuddin K, Manap NA. Occupational radiation exposure to anaesthetists from fluoroscopic projections during orthopaedic operative procedures. Clin Ter 2014; 165(4): 253-7.
[10]
Ismail S, Khan FA, Sultan N, Naqvi M. Radiation exposure of trainee anaesthetists. Anaesthesia 2006; 61(6): 9-14.
[11]
McGowan C, Heaton B, Stephenson RN. Occupational x-ray exposure of anaesthetists. Br J Anaesth 1996; 76(6): 868-9.
[12]
Vano E, Fernandez JM, Sanchez R. Occupational dosimetry in real time. Benefits for interventional radiology. Radiation Measurements 2011; 46(11): 1262-5.
[13]
Vaes B, Van Keer K, Stuelens L, et al. Eye lens dosimetry in anesthesiology a prospective study. J Clin Monit Comput 2017; 31(2): 303-8.
[14]
Sanchez R, Vano E, Fernandez JM, Gallego JJ. Staff radiation doses in a real-time display inside the angiography room. Cardiovasc Intervent Radiol 2010; 33(6): 1210-4.
[15]
Valentin J. The 2007 Recommendations of the International Commission on Radiological Protection. Ann ICRP 2007; 37: 1-332.
[16]
Mueller M, Rangger C, Striepens N, Burger C. Minimally invasive intramedullary nailing of midshaft clavicular fractures using titanium elastic nails. J Trauma 2008; 64(6): 1528-34.
[17]
Agarwal A. Radiation risk in orthopaedic surgery: Ways to protect yourself and the patient. Oper Tech Sports Med 2011; 19(4): 220-3.
[18]
Zabel EW, Alexander BH, Mongin SJ. Thyroid cancer and employment as a radiologic technologist. Int J Cancer 2006; 119(8): 1940-5.
[19]
Ronckers CM, Erdmann CA, Land CE. Radiation and breast cancer: a review of current evidence. Breast Cancer Res 2005; 7(1): 21-32.
[20]
Arii T, Uchino S, Kubo Y, Kiyama S, Uezono S. Radiation exposure to anaesthetists during endovascular procedures. Anaesthesia 2015; 70(1): 47-50.
[21]
Andreoli S, Moretti R, Lorini FL, Lagrotta M. Radiation exposure of an anaesthesiologist in catheterisation and electrophysiological cardiac procedures. Rad Protect Dosimet 2016; 168(1): 76-82.
[22]
Stewart FA, Akleyev AV, Hauer-Jensen M, et al. International commission on radiological protection 118. Ann ICRP 2012; 41(1/2)
[23]
Lewall DB, Riley P, Al Hassoon A, Mc Parland BJ. A fluoroscopy credentialing programme for orthopaedic surgeons. J Bone Joint Surg Br 1995; 77(3): 442-4.

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy