Generic placeholder image

Recent Patents on Engineering

Editor-in-Chief

ISSN (Print): 1872-2121
ISSN (Online): 2212-4047

Research Article

Study on Operating Characteristics of Hydro Generator with Different Damper Bar Materials

Author(s): Hongbo Qiu, Xiaobin Fan*, Hua Liu, Jianqin Feng and Cunxiang Yang

Volume 12, Issue 2, 2018

Page: [127 - 134] Pages: 8

DOI: 10.2174/1872212111666170817101711

Price: $65

Abstract

Background: Damper bar is an important component to ensure the security and stability operation of generator. Some patents have been proposed in recent years to deal with generator vibration. Based on the damages of damper bars appeared in many hydropower units, the influences of damper bar material on generator operating characteristics are analyzed.

Objective: This study aims to find the suitable material for damper bars to improve the reliable operation of generator.

Methods: In this research, a 24-MW bulb tubular turbine generator is taken as an example. The two dimensional model is established by using finite element software, and through the comparative analysis of test results and simulation data, the correctness of the model is verified. The analysis and handling of the electromagnetic parameters are based on the finite element method.

Results: The brass, copper iron alloy and copper, three kinds of materials are selected to study the effects of damper bar material on the air gap magnetic field and the saturation degree of the pole shoe magnetic density. At the same time, the influences of damper bar material on the generator losses, torques and eddy current are discussed.

Conclusion: The application of copper iron alloy material can reduce the saturation degree of the pole shoe magnetic density, pole-to-pole leakage, eddy current and torque ripple of the generator.

Keywords: Bulb tubular turbine generator, damper bar, losses, torque ripple, copper iron alloy, eddy current.

Graphical Abstract
[1]
F.J. Garcia, M.K.I. Uemori, J.J.R. Echeverria, and E.D. Costa Bortoni, "Design requirements of generators applied to low-head hydro power plants", IEEE Trans. Energ. Convers.. vol. 30, pp. 1630-1638, December 2015.
[2]
T.H. Sahebrao, and V.J. Murlidhar, "Design and manufacturing of Bulb Turbine", In: 1st International Conference on Automatic Control and Dynamic Optimization Techniques (ICACDOT 2016). Pune, 2017, pp. 194-197.
[3]
Y. Li, G. Song, and Y. Yan, "Transient hydrodynamic analysis of the transition process of bulb hydraulic turbine", Adv. Eng. Software. vol. 90, pp. 152-158, December 2015.
[4]
S. Nuzzo, M. Degano, M. Galea, C. Gerada, D. Gerada, and N. Brown, "Improved damper cage design for salient-pole synchronous generators", IEEE Trans. Ind. Electron.. vol. 64, pp. 1958- 1970, March 2017.
[5]
K. Kurihara, "Effects of damper bars on steady-state and transient performance of interior permanent-magnet synchronous generators", IEEE Trans. Ind. Appl.. vol. 49, pp. 42-49, January-February 2013.
[6]
M. Wallin, J. Bladh, and U. Lundin, "Damper winding influence on unbalanced magnetic pull in salient pole generators with rotor eccentricity", IEEE Trans. Magn.. vol. 49, pp. 5158-5165, September 2013.
[7]
J. Matsuki, H. Taoka, Y. Hayashi, S. Iwamoto, and A. Daikoku, "Improvement of three-phase unbalance due to connection of dispersed generator by damper windings of synchronous generator", Electr. Eng. Jpn.. vol. 186, pp. 43-50, January 2014.
[8]
Z.N. Fan, Y. Liao, L. Han, and L.D. Xie, "No-load voltage waveform optimization and damper bars heat reduction of tubular hydrogenerator by different degree of adjusting damper bar pitch and skewing stator slot", IEEE Trans. Energ. Convers.. vol. 28, pp. 461-469, September 2013.
[9]
M. Wallin, J. Bladh, and U. Lundin, "Damper winding influence on unbalanced magnetic pull in salient pole generators with rotor eccentricity", IEEE Trans. Magn.. vol. 49, pp. 5158-5165, September 2013.
[10]
G. Traxler-Samek, T. Lugand, and A. Schwery, "Additional losses in the damper winding of large hydrogenerators at open-circuit and load conditions", IEEE Trans. Ind. Electron.. vol. 57, pp. 154-160, January 2010.
[11]
M. Bergeron, J. Cros, J. Niehenke, J.R. Figueroa, and C. Messier, "Hydro generator damper bar current measurement at wanapum dam", IEEE Trans. Energ. Convers.. vol. 31, pp. 1510-1520, December 2016.
[12]
F.Y. Huo, W.L. Li, and D.M. Wang, "Influence of damper winding on electromagnetic parameters and additional loss of large hydro-generator", Electr. Mach. Contr.. vol. 15, pp. 89-94, May 2011.
[13]
A. Biebighäuser, and A. Ghita, Rotor for a rotating electrical machine. U.S. Patent 20160118851A1, 2016.
[14]
O.Y. Wen, J.Q. Liang, and Q. Li, Reducing peak fault output current in a DC power generation system. U.S. Patent 20170054393A1, 2017.
[15]
Z. Jajtic, G. Matscheko, and S. Schiele, Electrical machine with a damping winding. U.S. Patent 20090174266A1, 2009.
[16]
L.K. Wang, W.L. Li, F.Y. Huo, S.K. Zhang, and C.W. Guan, "Influence of underexcitation operation on electromagnetic loss in the end metal parts and stator step packets of a turbogenerator", IEEE Trans. Energ. Convers.. vol. 29, pp. 748-757, September 2014.
[17]
W.L. Li, H.B. Qiu, X.C. Zhang, J.C. Cao, and R. Yi, "Analyses on electromagnetic and temperature fields of superhigh-speed permanent-magnet generator with different sleeve materials", IEEE Trans. Ind. Electron.. vol. 61, pp. 3056-3063, June 2014.

Rights & Permissions Print Cite
© 2024 Bentham Science Publishers | Privacy Policy